Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Pesqui. vet. bras ; 38(2): 340-344, fev. 2018. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-895568

ABSTRACT

The agreement between the electrocardiographic waves measured from tracings recorded in right lateral recumbency and several other unusual body positions was assessed. Electrocardiograms were recorded in 160 healthy dogs in right lateral, left lateral, dorsal and sternal recumbencies, as well as in standing position. Considering the right lateral recordings as the gold standard, the lowest biases for the majority of ECG parameters were calculated from left lateral recordings, whereas the highest biases were documented from dorsal and standing positions. For the mean electrical axis, the dorsal recumbency produced the lowest bias, while the greatest one was identified in sternal position. An analysis of variance indicated differences when the means of P wave duration and amplitude, duration of QRS and QT, and mean electrical axis obtained in unusual positions were compared with right lateral. In conclusion, left lateral recumbency produced the most similar measurements as compared to right lateral, but the wide limits of agreement preclude the use and interpretation of these positions interchangeably.(AU)


A concordância entre a mensuração das ondas eletrocardiográficas a partir de traçados registrados em cães mantidos em decúbito lateral direito e em vários outros posicionamentos corporais foi avaliada nesta pesquisa. Para tanto, traçados eletrocardiográficos de 160 cães saudáveis foram registrados com os pacientes posicionados nos decúbitos lateral direito, lateral esquerdo, dorsal e esternal, assim como em posição quadrupedal. Tomando como padrão ouro os registros obtidos em decúbito lateral direito, as menores diferenças médias para a maioria dos parâmetros eletrocardiográficos foram obtidas a partir dos traçados registrados com o cão mantido em decúbito lateral esquerdo, enquanto as maiores diferenças médias foram documentadas nos registros obtidos nos decúbitos dorsal e quadrupedal. Para o eixo elétrico médio, o decúbito dorsal produziu a menor diferença média, enquanto a maior foi identificada no registro em posição esternal. A análise de variância mostrou diferenças entre as médias da duração e amplitude da onda P, duração do QRS e do intervalo QT e o eixo elétrico médico quando as posições não usuais foram comparadas com o decúbito lateral direito. Esta pesquisa mostrou que o decúbito lateral esquerdo produziu as medidas mais semelhantes quando comparado àquelas obtidas em decúbito lateral direito. No entanto, os limites de concordância amplos impedem que essas posições sejam utilizadas e interpretadas de maneira intercambiável.(AU)


Subject(s)
Animals , Dogs , Electrocardiography/statistics & numerical data , Electrocardiography/veterinary , Patient Positioning/veterinary , Analysis of Variance , Outcome Assessment, Health Care/methods
2.
Arq. bras. med. vet. zootec. (Online) ; 69(6): 1419-1425, nov.-dez. 2017. ilus
Article in English | LILACS, VETINDEX | ID: biblio-909829

ABSTRACT

Radiation therapy is a modality that is presenting great advances in veterinary medicine worldwide. In Brazil, this therapeutic option is underachieved. The success of this method depends on several factors, including the use of appropriate accessories for protection and immobilization of patients. For the immobilization of small animals during treatment, in addition to sedation and anesthesia, immobilizing accessories, similar to those used in human radiotherapy, are used. This study aimed to present proposals for immobilizing accessories adapted to the positioning of small animals in order to be used in radiotherapy planning. In order to achieve results, accessories were made and tested in a living animal simulating a radiotherapy planning, which proved to be favorable to use in positioning small animals undergoing radiotherapy and for implementation processes.(AU)


A radioterapia é uma modalidade que tem apresentando grandes avanços dentro da medicina veterinária pelo mundo. No Brasil, essa opção terapêutica é pouco realizada. O sucesso dessa modalidade depende de vários fatores, entre eles, o uso de acessórios adequados para a proteção e imobilização dos pacientes. Para a imobilização dos pequenos animais durante o tratamento, além da sedação e da anestesia, são utilizados acessórios imobilizadores semelhantes aos usados na radioterapia humana. Devido a isso, este trabalho teve como objetivo de apresentar propostas de acessórios de imobilização adaptados ao posicionamento de pequenos animais para o uso nos planejamentos radioterápicos. Para a sua realização, foram confeccionados acessórios e testados em um animal vivo simulando um planejamento radioterápico, os quais mostraram ser favoráveis ao uso nos posicionamento de pequenos animais submetidos à radioterapia e para sua implementação.(AU)


Subject(s)
Animals , Female , Dogs , Equipment and Supplies/veterinary , Immobilization/instrumentation , Immobilization/veterinary , Radiotherapy/veterinary , Patient Positioning/veterinary
3.
Arq. bras. med. vet. zootec. (Online) ; 69(6): 1456-1460, nov.-dez. 2017. ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-910031

ABSTRACT

O objetivo deste trabalho foi demonstrar que o posicionamento radiográfico inadequado do membro pélvico de cães (imagens obliquadas) afeta a mensuração do ângulo do platô tibial (APT), levando à maior variação entre observadores. Foram realizadas duas projeções radiográficas nos membros pélvicos direito e esquerdo, uma em perfil verdadeiro e a outra com o membro obliquado em 21 cães provenientes do atendimento clínico cirúrgico do Hospital Veterinário da Universidade de Cuiabá, em Cuiabá-MT. Os critérios de inclusão foram cães livres de histórico ou afecção ortopédica nos membros pélvicos, pesando entre 15 e 40 quilos, sem predileção por raça ou sexo, entre dois e sete anos de idade. Foram obtidas 42 imagens radiográficas em perfil verdadeiro e 42 imagens radiográficas obliquadas. Três observadores com experiência em cálculo do APT fizeram as mensurações. Nos cálculos das imagens em perfil verdadeiro, o observador 1 obteve uma média de 23,35º ± 2,82; o observador 2, média de 23,88º ± 4,83; e o observador 3, média de 24,54º ± 4,01, não sendo encontrada diferença significativa entre o cálculo dos três avaliadores, P=0,944 (P > 0,05), nas imagens em perfil verdadeiro. Nos cálculos das imagens obliquadas, o observador 1 obteve uma média de 21,69º ± 4,22; o observador 2, média de 19,42º ± 5,92; e o observador 3, média de 22,64º ± 5,23, e foi encontrada diferença significativa entre o cálculo dos três observadores, P=0,016 (P < 0,05). Com esses dados, pôde-se demonstrar que a imagem radiográfica obliquada compromete o valor final do cálculo do ângulo do platô tibial em cães, levando à variação numérica estatisticamente significativa entre observadores. Conclui-se, assim, que um posicionamento correto do membro pélvico, em perfil verdadeiro, deve ser sempre utilizado para a obtenção de imagens, com o objetivo de mensurar o valor do APT.(AU)


This work aimed at demonstrating that an inadequate radiographic position of pelvic limbs of dogs, from a strict lateral radiographic view, resulted in oblique images, affecting the measurement of the tibial plateau angle (TPA). There were two radiographic projections of the right and the left pelvic limb, one in strict lateral radiographic view and another with inclined hind limb in 21 dogs from the clinical surgical assistance at Hospital Veterinário of Universidade de Cuiabá in Cuiabá-MT. Inclusion criteria were dogs free from pelvic hind limbs orthopedic affection records, weighing between 15 and 40 kilos, without a preference for breed or gender and ageing between two and seven years old. A total of 42 radiographic images in strict lateral radiographic view and 42 inclined limb radiographic views were obtained. Three observers with TPA calculation experience made measurements. In the calculus for the strict lateral radiographic view the first observer has reached an average of 23,35º ± 2,82, the second observer 23,88º ± 4,83 and the third observer 24,54º ± 4,01. No significant statistic differences among the calculus of the three evaluators p=0,944 (P>0,05) was found. In the calculus of the inclined limbs radiographic views the first observer reached an average of 21,69º ± 4,22, the second observer 19,42º ± 5,92 and the third observer 22,64º ±. 5,23. Significant statistic difference in the calculus of the three observers, p=0,016, that is to say, P<0,05 was found. The data indicated that the inclined limb radiographic image compromises the final value of the calculation of tibial plateau angle in dogs. Thus, correct positioning of the pelvic limb, in a strict lateral radiographic view, must be always used for obtaining images aiming at measuring the value of TPA.(AU)


Subject(s)
Animals , Dogs , Ligaments, Articular/diagnostic imaging , Patient Positioning/veterinary , Pelvis/diagnostic imaging , Tibia/anatomy & histology , Anterior Cruciate Ligament Injuries/veterinary , Osteotomy/veterinary
SELECTION OF CITATIONS
SEARCH DETAIL